Overview
POWERSHIELD Commander 2000VA Line Interactive Tower UPS. Delivers Automatic Emergency AC Power Generated from Internal DC Batteries. Tower case UPS with Backlit LCD. Pure Sine Wave Output.
Specifications
EMC
| EMC | EN62040-2 2006 |
|---|
RoHS
| RoHS | Directive 2011/65/EU |
|---|
Safety
| Safety | EN62040-1 -1 2003, IEC 60950-1 -1 |
|---|
Weight
| Weight | 20.5/22.5kg |
|---|
AC Mode
| AC Mode | 98% (Advanced ECO design) |
|---|
Capacity
| Capacity | 2000VA/1800W |
|---|
Software
| Software | PowerShield NetGuard® software - supports Windows-based operating system, Linux, Unix and Mac |
|---|
Topology
| Topology | Line Interactive, Pure Sine Wave |
|---|
Frequency
| Frequency | 50/60Hz ±5Hz (auto sensing) |
|---|
Interface
| Interface | USB and RS-232 as standard, an Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact |
|---|
LCD display
| LCD display | AC mode, Batt. Mode, Load Level, Input Voltage, Output Voltage, Overload, Fault, Battery Replacement, Low Batt., Batt. Time Remaining |
|---|
Noise Level
| Noise Level | <45dB |
|---|
Weight (34)
| Weight (34) | COMPLIANCE |
|---|
Battery Mode
| Battery Mode | 91% |
|---|
Topology (2)
| Topology (2) | INPUT |
|---|
Audible alarm
| Audible alarm | Battery Mode, Low Battery (Batt. Mode), Battery Replacement, Fault, Overload |
|---|
Frequency (6)
| Frequency (6) | OUTPUT |
|---|
Transfer Time
| Transfer Time | 6ms (Typical), 10ms max. |
|---|
Standard Model
| Standard Model | Battery Type & Number: 12V/9AH (x4)Recharge Time: 4 hours recover to 90% capacity |
|---|
Full Protection
| Full Protection | Overload, thermal, short circuit, discharge and overcharge protection |
|---|
Nominal Voltage
| Nominal Voltage | 240V AC |
|---|
Noise Level (26)
| Noise Level (26) | COMMUNICATIONS & MANAGEMENT |
|---|
Surge Protection
| Surge Protection | 1968J/39000A |
|---|
Battery Mode (17)
| Battery Mode (17) | BATTERY |
|---|
Relative Humidity
| Relative Humidity | 0%~90% (RH non-condensing) |
|---|
Audible alarm (31)
| Audible alarm (31) | PHYSICAL |
|---|
Current Crest Ratio
| Current Crest Ratio | 3.1 |
|---|
Standard Model (19)
| Standard Model (19) | PROTECTION |
|---|
Operation Temperature
| Operation Temperature | 0°C~40°C |
|---|
Surge Protection (22)
| Surge Protection (22) | ENVIRONMENT |
|---|
Waveform (Batt. Mode)
| Waveform (Batt. Mode) | Pure Sine Wave |
|---|
Dimensions (D x W x H)
| Dimensions (D x W x H) | 455 x 145 x 220mm |
|---|
Acceptable Voltage Range
| Acceptable Voltage Range | 162-290V AC |
|---|
Total Harmonic Distortion
| Total Harmonic Distortion | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) |
|---|
Waveform (Batt. Mode) (14)
| Waveform (Batt. Mode) (14) | EFFICIENCY |
|---|
Frequency Range (Batt. Mode)
| Frequency Range (Batt. Mode) | 50Hz or 60Hz ±1Hz |
|---|
Voltage Regulation (AC Mode)
| Voltage Regulation (AC Mode) | 240V AC (Selectable 208/220/230V AC) ±10% AVR |
|---|
Voltage Regulation (Batt. Mode)
| Voltage Regulation (Batt. Mode) | ± 1.5% (before battery alarm) |
|---|