POWERSHIELD Commander 2000VA Line Interactive Tower UPS. Delivers

  • Brand: Powershield
  • Category: UPS Systems
  • SKU: PSCM2000
  • MPN: PSCM2000
Powershield

POWERSHIELD Commander 2000VA Line Interactive Tower UPS. Delivers

SKU
CNZ-CD-004450
MPN
PSCM2000

Overview

POWERSHIELD Commander 2000VA Line Interactive Tower UPS. Delivers Automatic Emergency AC Power Generated from Internal DC Batteries. Tower case UPS with Backlit LCD. Pure Sine Wave Output.

Specifications

EMC

EMCEN62040-2 2006

RoHS

RoHSDirective 2011/65/EU

Safety

SafetyEN62040-1 -1 2003, IEC 60950-1 -1

Weight

Weight20.5/22.5kg

AC Mode

AC Mode98% (Advanced ECO design)

Capacity

Capacity2000VA/1800W

Software

SoftwarePowerShield NetGuard® software - supports Windows-based operating system, Linux, Unix and Mac

Topology

TopologyLine Interactive, Pure Sine Wave

Frequency

Frequency50/60Hz ±5Hz (auto sensing)

Interface

InterfaceUSB and RS-232 as standard, an Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact

LCD display

LCD displayAC mode, Batt. Mode, Load Level, Input Voltage, Output Voltage, Overload, Fault, Battery Replacement, Low Batt., Batt. Time Remaining

Noise Level

Noise Level<45dB

Weight (34)

Weight (34)COMPLIANCE

Battery Mode

Battery Mode91%

Topology (2)

Topology (2)INPUT

Audible alarm

Audible alarmBattery Mode, Low Battery (Batt. Mode), Battery Replacement, Fault, Overload

Frequency (6)

Frequency (6)OUTPUT

Transfer Time

Transfer Time6ms (Typical), 10ms max.

Standard Model

Standard ModelBattery Type & Number: 12V/9AH (x4)Recharge Time: 4 hours recover to 90% capacity

Full Protection

Full ProtectionOverload, thermal, short circuit, discharge and overcharge protection

Nominal Voltage

Nominal Voltage240V AC

Noise Level (26)

Noise Level (26)COMMUNICATIONS & MANAGEMENT

Surge Protection

Surge Protection1968J/39000A

Battery Mode (17)

Battery Mode (17)BATTERY

Relative Humidity

Relative Humidity0%~90% (RH non-condensing)

Audible alarm (31)

Audible alarm (31)PHYSICAL

Current Crest Ratio

Current Crest Ratio3.1

Standard Model (19)

Standard Model (19)PROTECTION

Operation Temperature

Operation Temperature0°C~40°C

Surge Protection (22)

Surge Protection (22)ENVIRONMENT

Waveform (Batt. Mode)

Waveform (Batt. Mode)Pure Sine Wave

Dimensions (D x W x H)

Dimensions (D x W x H)455 x 145 x 220mm

Acceptable Voltage Range

Acceptable Voltage Range162-290V AC

Total Harmonic Distortion

Total Harmonic Distortion2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm)

Waveform (Batt. Mode) (14)

Waveform (Batt. Mode) (14)EFFICIENCY

Frequency Range (Batt. Mode)

Frequency Range (Batt. Mode)50Hz or 60Hz ±1Hz

Voltage Regulation (AC Mode)

Voltage Regulation (AC Mode)240V AC (Selectable 208/220/230V AC) ±10% AVR

Voltage Regulation (Batt. Mode)

Voltage Regulation (Batt. Mode)± 1.5% (before battery alarm)

Questions

$1,605.39inc GST