APC Smart-UPS SMC Series Line Interactive. 1000VA (600W) 2U Rack
- Brand: APC
- Category: Uninterruptible Power Supplies (upss)
- SKU: SMC1000I-2UC
- MPN: SMC1000I-2UC
APC
APC Smart-UPS C, Line Interactive, 1000VA, Rackmount 2U, 230V, 4x…
- SKU
- CNZ-CD-004498
- MPN
- SMC1000I-2UC
- Rating
- No reviews yet
−7%
Overview
APC Smart-UPS SMC Series Line Interactive. 1000VA (600W) 2U Rack Mount. 230V Input/Output. 6x IEC C13 Outlets. Battery Backup LED Status Indicators. USB Connectivity Audible Alarm. Rach Mount Included
Key features
- UPS topology: Line-Interactive
- Output power capacity: 1 kVA
- Output power: 600 W
- Waveform: Sine
- Input operation voltage (min): 170 V
- Input operation voltage (max): 300 V
- Input frequency: 50/60 Hz
- Output operation voltage (min): 220 V
- Output operation voltage (max): 240 V
- Output frequency: 50/60 Hz
- Automatic Voltage Regulation (AVR): Yes
- Surge energy rating: 680 J
- Output voltage Total Harmonic Distortion (THD): 5%
- Noise level: 41 dB
- Surge protection: Yes
- Audible alarm(s): Yes
- Audible alarm modes: Alarm when on battery, Low battery alarm, Overload alarm
- AC outlet types: C13 coupler
- Power plug: C14 coupler
- AC outlets quantity: 4 AC outlet(s)
- USB port: Yes
- USB 2.0 ports quantity: 1
- Serial interface: Yes
- Serial interface type: RS-232
Specifications
RoHS
| RoHS | Compliant |
|---|
Spec
| Spec | Output |
|---|
Colour
| Colour | Black |
|---|
Topology
| Topology | Line-interactive |
|---|
Approvals
| Approvals | C-Tick, CE, GOST, UL 1778, VDE |
|---|
Filtering
| Filtering | Full-time multi-pole noise filtering: 0.3% IEEE surge let-through: zero clamping response time: meets UL 1449 |
|---|
Net Weight
| Net Weight | 20.52KG |
|---|
Rack Height
| Rack Height | 2U |
|---|
Battery type
| Battery type | Lead-acid battery |
|---|
RBC Quantity
| RBC Quantity | 1 |
|---|
Audible Alarm
| Audible Alarm | Alarm when on battery: distinctive low battery alarm: configurable delays |
|---|
Control panel
| Control panel | Multifunction LCD status and control console |
|---|
Maximum Depth
| Maximum Depth | 406MM, 40.6CM |
|---|
Maximum Width
| Maximum Width | 432MM, 43.2CM |
|---|
Transfer Time
| Transfer Time | 6 ms typical:10ms maximum |
|---|
Waveform type
| Waveform type | Sine wave |
|---|
Filtering (31)
| Filtering (31) | Physical |
|---|
Maximum Height
| Maximum Height | 86MM, 8.6CM |
|---|
Shipping Depth
| Shipping Depth | 584MM, 58.4CM |
|---|
Shipping Width
| Shipping Width | 546MM, 54.6CM |
|---|
Input frequency
| Input frequency | 50/60Hz +/- 3Hz Auto-sensing |
|---|
Shipping Height
| Shipping Height | 241MM, 24.1CM |
|---|
Shipping weight
| Shipping weight | 22.33KG |
|---|
Standard warrant
| Standard warrant | 2 years repair or replace |
|---|
Units per Pallet
| Units per Pallet | 16.0 |
|---|
Input Connections
| Input Connections | IEC 320 C14 |
|---|
Interface Port(s)
| Interface Port(s) | RJ-45 Serial, USB |
|---|
Storage Elevation
| Storage Elevation | 0~15240meters |
|---|
Audible Alarm (28)
| Audible Alarm (28) | Surge Protection and Filtering |
|---|
Output Connections
| Output Connections | (4) IEC 320 C13(2) IEC Jumpers |
|---|
Transfer Time (11)
| Transfer Time (11) | Input |
|---|
Operating Elevation
| Operating Elevation | 0~3048 meters |
|---|
Storage Temperature
| Storage Temperature | -15°C~45°C |
|---|
Surge energy rating
| Surge energy rating | 459 Joules |
|---|
Other Input Voltages
| Other Input Voltages | 220, 240 |
|---|
Nominal Input Voltage
| Nominal Input Voltage | 230V |
|---|
Number of Power Cords
| Number of Power Cords | 1 |
|---|
Operating Temperature
| Operating Temperature | 0°C-~40°C |
|---|
Other Output Voltages
| Other Output Voltages | 220, 240 |
|---|
Output power capacity
| Output power capacity | 600 Watts / 1.0kVA |
|---|
Standard warrant (54)
| Standard warrant (54) | Sustainable Offer Status |
|---|
Typical recharge time
| Typical recharge time | 3 hour(s) |
|---|
Units per Pallet (43)
| Units per Pallet (43) | Environmental |
|---|
Nominal Output Voltage
| Nominal Output Voltage | 230V |
|---|
Other Input Voltages (18)
| Other Input Voltages (18) | Batteries & Runtime |
|---|
Output Voltage Distortion
| Output Voltage Distortion | Less than 5% |
|---|
Online thermal dissipation
| Online thermal dissipation | 46.0BTU/hr |
|---|
Operating Relative Humidity
| Operating Relative Humidity | 0%~95% |
|---|
Battery Charge Power (Watts)
| Battery Charge Power (Watts) | 72 Watts |
|---|
Expected Battery Life (years)
| Expected Battery Life (years) | 4 - 6 |
|---|
Max Configurable Power (Watts)
| Max Configurable Power (Watts) | 600 Watts / 1.0kVA |
|---|
Online thermal dissipation (51)
| Online thermal dissipation (51) | Conformance |
|---|
Output Frequency (sync to mains)
| Output Frequency (sync to mains) | 50/60Hz +/-3Hz Sync to mains |
|---|
Battery Charge Power (Watts) (24)
| Battery Charge Power (Watts) (24) | Communications & Management |
|---|
Input voltage range for main operations
| Input voltage range for main operations | 170 - 300 Adjustable, 180V~287V |
|---|
Audible noise at 1 meter from surface of the unit
| Audible noise at 1 meter from surface of the unit | 42.0dBA |
|---|